{"id":1259,"date":"2013-09-17T11:50:01","date_gmt":"2013-09-17T09:50:01","guid":{"rendered":"http:\/\/wp.unil.ch\/lge\/?page_id=1259"},"modified":"2013-10-09T15:36:26","modified_gmt":"2013-10-09T13:36:26","slug":"icp-optical-emission-spectrometer-optima-8300","status":"publish","type":"page","link":"https:\/\/wp.unil.ch\/lge\/analytical-instruments\/icp-optical-emission-spectrometer-optima-8300\/","title":{"rendered":"ICP Optical Emission Spectrometer Optima 8300"},"content":{"rendered":"<p><strong><a href=\"https:\/\/wp.unil.ch\/lge\/files\/2013\/09\/ICP.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-thumbnail wp-image-1207\" alt=\"ICP\" src=\"https:\/\/wp.unil.ch\/lge\/files\/2013\/09\/ICP-150x150.jpg\" width=\"150\" height=\"150\" \/><\/a>1235 G\u00e9opolis<\/strong><br \/>\n<strong>Contact<\/strong> :<br \/>\nAnna Simanova<br \/>\nJasquelin Pe\u00f1a<br \/>\n<strong>Email<\/strong> :<br \/>\n<a href=\"mailto:Anna.Simanova@unil.ch\">anna.simanova@unil.ch<\/a><br \/>\n<strong>Tel<\/strong> : (021) 692-4312<\/p>\n<p>&nbsp;<\/p>\n<hr noshade=\"noshade\" width=\"100%\" \/>\n<p>The <a href=\"https:\/\/www.perkinelmer.com\/CH\/Catalog\/Product\/ID\/OPTIMA8300\"><strong>Perkin Elmer Optima 8300 ICP-OES<\/strong><\/a> allows for simultaneous elemental analysis. Measurements are made by introduction of an aqueous sample into a high-temperature (8000oC) argon plasma. The intensity of light emitted by thermally excited elements at characteristic wavelengths is measured and related to elemental concentration.<\/p>\n<p>The instrument is equipped with an auto-sampler that can accommodate 100 samples. About 3 minutes are required to analyze each sample. A minimum sample volume of 3 &#8211; 5 ml is needed. The detection limit is around 0.5\u00b5M, but depends on the element(s) being analyzed and the sample matrix. The instrument gives a linear response over 3 &#8211; 4 orders of magnitude in concentration (e.g., 0.1 \u2013 500 mM Mn).<\/p>\n<p>Samples MUST be filtered to remove all particles and acidified prior to analysis. Samples must be diluted to have a total dissolved solids concentration of &lt; 1 % TDS (Meinhard concentric glass nebulizer + cyclonic spray chamber) or &lt; 10% (PEEK Mira Mist Nebulizer + baffled cyclonic spray chamber).<\/p>\n<p>For further information read:<\/p>\n<p><strong>Hou, X., &amp; Jones, B. T.<\/strong> (2006). Inductively Coupled Plasma-Optical Emission Spectrometry. In Encyclopedia of Analytical Chemistry (pp. 9468-9485). John Wiley &amp; Sons, Ltd.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>1235 G\u00e9opolis Contact : Anna Simanova Jasquelin Pe\u00f1a Email : anna.simanova@unil.ch Tel : (021) 692-4312 &nbsp; The Perkin Elmer Optima 8300 ICP-OES allows for simultaneous elemental analysis. Measurements are made &hellip; <\/p>\n","protected":false},"author":982,"featured_media":0,"parent":1205,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","ngg_post_thumbnail":0,"footnotes":""},"class_list":["post-1259","page","type-page","status-publish"],"_links":{"self":[{"href":"https:\/\/wp.unil.ch\/lge\/wp-json\/wp\/v2\/pages\/1259","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wp.unil.ch\/lge\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/wp.unil.ch\/lge\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/wp.unil.ch\/lge\/wp-json\/wp\/v2\/users\/982"}],"replies":[{"embeddable":true,"href":"https:\/\/wp.unil.ch\/lge\/wp-json\/wp\/v2\/comments?post=1259"}],"version-history":[{"count":0,"href":"https:\/\/wp.unil.ch\/lge\/wp-json\/wp\/v2\/pages\/1259\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/wp.unil.ch\/lge\/wp-json\/wp\/v2\/pages\/1205"}],"wp:attachment":[{"href":"https:\/\/wp.unil.ch\/lge\/wp-json\/wp\/v2\/media?parent=1259"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}