{"id":1370,"date":"2022-02-25T17:22:08","date_gmt":"2022-02-25T16:22:08","guid":{"rendered":"https:\/\/wp.unil.ch\/gtf\/?page_id=1370"},"modified":"2026-03-19T10:55:32","modified_gmt":"2026-03-19T09:55:32","slug":"technology","status":"publish","type":"page","link":"https:\/\/wp.unil.ch\/gtf\/technology\/","title":{"rendered":"PacBio Technology"},"content":{"rendered":"\n<p class=\"has-medium-font-size\"><span style=\"text-decoration: underline\"><strong>Overview<\/strong><\/span><\/p>\n\n\n\n<p>Being early adopters of the <strong>Pacific Biosciences sequencing technology<\/strong>, we now have more than 12 years\u2019 experience with long read sequencing. We currently run the latest Pacific Biosciences <a href=\"https:\/\/www.pacb.com\/revio\/\" target=\"_blank\" rel=\"noreferrer noopener\">Revio system<\/a>.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"556\" height=\"468\" src=\"https:\/\/wp.unil.ch\/gtf\/files\/2026\/03\/revio-smrt-cell-2.jpg\" alt=\"revio smrt cell\" class=\"wp-image-2059\" style=\"width:397px;height:auto\" srcset=\"https:\/\/wp.unil.ch\/gtf\/files\/2026\/03\/revio-smrt-cell-2.jpg 556w, https:\/\/wp.unil.ch\/gtf\/files\/2026\/03\/revio-smrt-cell-2-300x253.jpg 300w\" sizes=\"auto, (max-width: 556px) 100vw, 556px\" \/><\/figure>\n<\/div>\n\n\n<p><strong>Main applications are:<\/strong><br><strong>\u2022<\/strong> <em>De novo<\/em> genome sequencing (any type, from small bacterial genomes to large, complex animal or plant genomes)<br><strong>\u2022<\/strong> Nucleotide and structural variant analysis<br><strong>\u2022<\/strong> DNA base modification analysis (epigenetics) <br><strong>\u2022<\/strong> Full length RNA isoform sequencing (including single cell analysis)<br><strong>\u2022<\/strong> Long amplicon sequencing (1 kb to 10 kb, Sanger-like quality)<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-medium-font-size\"><span style=\"text-decoration: underline\"><strong>PacBio SMRT sequencing<\/strong><\/span><\/p>\n\n\n\n<p>Pacific Biosciences libraries molecules are circular<\/p>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\" style=\"grid-template-columns:68% auto\"><figure class=\"wp-block-media-text__media\"><img alt=\"\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"459\" src=\"https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/02_SMRTbell-1024x459.png\" alt=\"\" class=\"wp-image-1298 size-full\" srcset=\"https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/02_SMRTbell-1024x459.png 1024w, https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/02_SMRTbell-300x134.png 300w, https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/02_SMRTbell-768x344.png 768w, https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/02_SMRTbell.png 1281w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p class=\"has-small-font-size\"><em>Source: <\/em><a href=\"https:\/\/www.pacb.com\/wp-content\/uploads\/SMRT-Sequencing-Brochure-Delivering-highly-accurate-long-reads-to-drive-discovery-in-life-science.pdf\"><em>Pacific Biosciences<\/em><\/a><\/p>\n<\/div><\/div>\n\n\n\n<p>They are loaded in a SMRT cell for Single Molecule Real Time sequencing. Sequencing movies can last for up to 30 hours.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img alt=\"\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"460\" src=\"https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/03_SMRTCell-1024x460.png\" alt=\"\" class=\"wp-image-1299\" srcset=\"https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/03_SMRTCell-1024x460.png 1024w, https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/03_SMRTCell-300x135.png 300w, https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/03_SMRTCell-768x345.png 768w, https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/03_SMRTCell-1536x690.png 1536w, https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/03_SMRTCell.png 1703w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><br><em>Source: <\/em><a href=\"https:\/\/www.pacb.com\/wp-content\/uploads\/SMRT-Sequencing-Brochure-Delivering-highly-accurate-long-reads-to-drive-discovery-in-life-science.pdf\"><em>Pacific Biosciences<\/em><\/a><\/figcaption><\/figure>\n\n\n\n<p>A SMRT cell is 25M wells in total. Loading must be fine-tuned to ensure maximum occupancy without getting multiple Library\/Polymerase complexes per well. Depending on the library type, the output is generally 8M to 10M reads per run.<\/p>\n\n\n\n<p>The actual yield in Gb varies depending on the library quality and can typically reach more than 100 Gb with optimal conditions.<\/p>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img alt=\"\" loading=\"lazy\" decoding=\"async\" width=\"681\" height=\"521\" src=\"https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/04_Readlength.png\" alt=\"\" class=\"wp-image-1300 size-full\" srcset=\"https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/04_Readlength.png 681w, https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/04_Readlength-300x230.png 300w\" sizes=\"auto, (max-width: 681px) 100vw, 681px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p class=\"has-small-font-size\">In house example of a 120 Gb raw read output run: Read length distribution<\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-medium-font-size\"><span style=\"text-decoration: underline\"><strong>HiFi reads<\/strong><\/span><\/p>\n\n\n\n<p>Because Pacific Biosciences library molecules are circular, the same DNA insert molecule, if not too long, can be read many times over the course of a sequencing run. All the raw reads coming from the same single insert can be aligned and corrected, generating a high quality read called CCS (for Circular Consensus Sequence, see figure below) or HiFi read.<\/p>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\" style=\"grid-template-columns:72% auto\"><figure class=\"wp-block-media-text__media\"><img alt=\"\" loading=\"lazy\" decoding=\"async\" width=\"867\" height=\"902\" src=\"https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/05_HiFi.png\" alt=\"\" class=\"wp-image-1301 size-full\" srcset=\"https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/05_HiFi.png 867w, https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/05_HiFi-288x300.png 288w, https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/05_HiFi-768x799.png 768w\" sizes=\"auto, (max-width: 867px) 100vw, 867px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p class=\"has-small-font-size\"><em>Source: <\/em><a href=\"https:\/\/www.pacb.com\/wp-content\/uploads\/SMRT-Sequencing-Brochure-Delivering-highly-accurate-long-reads-to-drive-discovery-in-life-science.pdf\"><em>Pacific Biosciences<\/em><\/a><\/p>\n<\/div><\/div>\n\n\n\n<p>Typical CCS read metrics (read length and quality) are shown below.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img alt=\"\" loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"386\" src=\"https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/06_CCSMetrics-1024x386.png\" alt=\"\" class=\"wp-image-1303\" srcset=\"https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/06_CCSMetrics-1024x386.png 1024w, https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/06_CCSMetrics-300x113.png 300w, https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/06_CCSMetrics-768x290.png 768w, https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/06_CCSMetrics-1536x580.png 1536w, https:\/\/wp.unil.ch\/gtf\/files\/2022\/02\/06_CCSMetrics.png 1773w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><em>In house example of a 35 Gb HiFi reads output run: Insert length (left panel) and read quality (right panel) distribution<\/em><\/figcaption><\/figure>\n\n\n\n<p>HiFi reads are not ultra-long but, thanks to their <strong>ultra-high accuracy<\/strong> and <strong>uniform coverage<\/strong> over the genome (no GC bias), they are ideal for many applications such as phased assembly and variant analysis. No short sequencing read based error correction is required.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Overview Being early adopters of the Pacific Biosciences sequencing technology, we now have more than 12 years\u2019 experience with long read sequencing. We currently run the latest Pacific Biosciences Revio system. Main applications are:\u2022 De novo genome sequencing (any type,<\/p>\n","protected":false},"author":1002106,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","footnotes":""},"class_list":["post-1370","page","type-page","status-publish"],"_links":{"self":[{"href":"https:\/\/wp.unil.ch\/gtf\/wp-json\/wp\/v2\/pages\/1370","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wp.unil.ch\/gtf\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/wp.unil.ch\/gtf\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/wp.unil.ch\/gtf\/wp-json\/wp\/v2\/users\/1002106"}],"replies":[{"embeddable":true,"href":"https:\/\/wp.unil.ch\/gtf\/wp-json\/wp\/v2\/comments?post=1370"}],"version-history":[{"count":4,"href":"https:\/\/wp.unil.ch\/gtf\/wp-json\/wp\/v2\/pages\/1370\/revisions"}],"predecessor-version":[{"id":2063,"href":"https:\/\/wp.unil.ch\/gtf\/wp-json\/wp\/v2\/pages\/1370\/revisions\/2063"}],"wp:attachment":[{"href":"https:\/\/wp.unil.ch\/gtf\/wp-json\/wp\/v2\/media?parent=1370"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}